<entry>
   <title>Small-X Panel</title>
   <link rel="alternate" type="text/html" href="http://www.retrotec.com/products/door_panel_systems_and_parts/smallx_panel/" />
   <id>tag:www.retrotec.com,2007:/products//2.168</id>
   
   <published>2007-09-03T19:16:56Z</published>
   <updated>2007-10-05T17:31:55Z</updated>
   
   <summary>Small X Panel - extends the panel height by 10.5 in. Width adjust from 29 in. to 49 in. Optional with all hard panel sets. The small-x panel is a recommended option for customers using two of our modular fan...</summary>
   <author>
      <name>Skot Nelson</name>
      
   </author>
   
      <category term="Door Panel Systems and Parts" scheme="http://www.sixapart.com/ns/types#category" />
   
   <category term="92" label="Panels" scheme="http://www.sixapart.com/ns/types#tag" />
   
   <content type="html" xml:lang="en" xml:base="http://www.retrotec.com/products/">
      Small X Panel - extends the panel height by 10.5 in. Width adjust from 29 in. to 49 in.  Optional with all hard panel sets.

The small-x panel is a recommended option for customers using two of our modular fan panels. In these cases the standard XY Panel may be too tall for the remaining doorway height.

h3. Panel Dimensions

||*Inches*|*Centimeters*|
|*Height*|10.5.|26|
|*Mininum Width*|29|74|
|*Maximum Width*|49|124|
      
   </content>
</entry>

<entry>
   <title>Deluxe Cordura Toolbag</title>
   <link rel="alternate" type="text/html" href="http://www.retrotec.com/products/accessories/deluxe_cordura_toolbag/" />
   <id>tag:www.retrotec.com,2007:/products//2.156</id>
   
   <published>2007-08-15T15:28:55Z</published>
   <updated>2007-10-15T17:36:00Z</updated>
   
   <summary>This custom toolbag is recommended for all applications as a way to keep you door-fan accessories together and organized. This bag has pockets for laptop, printer, grille mask, tools, tape measure, clipboard and most importantly 3 pockets on the outside...</summary>
   <author>
      <name>Skot Nelson</name>
      
   </author>
   
      <category term="Accessories" scheme="http://www.sixapart.com/ns/types#category" />
   
   <category term="96" label="Toolbag" scheme="http://www.sixapart.com/ns/types#tag" />
   
   <content type="html" xml:lang="en" xml:base="http://www.retrotec.com/products/">
      This custom toolbag is recommended for all applications as a way to keep you door-fan accessories together and organized.  This bag has pockets for laptop, printer, grille mask, tools, tape measure, clipboard and most importantly 3 pockets on the outside for the air current testers to protect sensitive equipment from the smoke.

The deluxe cordura toolbag is included as a standard component with &quot;Retrotec&apos;s QMG three fan blower door system&quot;:/products/blower_door_systems/three_fan_systems/qmg_blower_door/ and fits all three of the included 3300 Fan power supplies. It&apos;s also a convenient carrying case for both the &quot;Q32 Duct Testing System&quot;:/products/duct_testing_systems/q32_ductester/ and the &quot;R31 Duct Testing System&quot;:/duct_testing_systems/r31_economy_duct_tester/, conveniently fitting the entire system into a single compact package.

|*Dimensions:*|26&quot; x 14.5&quot; x 15&quot;|
||66 cm x 37 cm x 38 cm|

      
   </content>
</entry>

<entry>
   <title>Low Flow Fan Field Calibration Plate</title>
   <link rel="alternate" type="text/html" href="http://www.retrotec.com/products/accessories/field_calibration_plate/" />
   <id>tag:www.retrotec.com,2007:/products//2.138</id>
   
   <published>2007-06-04T15:20:20Z</published>
   <updated>2007-11-29T17:24:53Z</updated>
   
   <summary>Retrotec&apos;s Field Calibration Plate for duct testing systems gives you an easy, five minute test to verify the accuracy of your duct testing system. Performing this test monthly will allow you to detect calibration problems early and fix them before...</summary>
   <author>
      <name>Skot Nelson</name>
      
   </author>
   
      <category term="Accessories" scheme="http://www.sixapart.com/ns/types#category" />
   
      <category term="Duct Testing Systems" scheme="http://www.sixapart.com/ns/types#category" />
   
   
   <content type="html" xml:lang="en" xml:base="http://www.retrotec.com/products/">
      Retrotec&apos;s Field Calibration Plate for duct testing systems gives you an easy, five minute test to verify the accuracy of your duct testing system. Performing this test monthly will allow you to detect calibration problems early and fix them before they become serious.

The field calibration plate is compatible with Retrotec&apos;s &quot;Q32&quot;:http://www.retrotec.com/products/duct_testing_systems/q32_ductester/ and &quot;R31&quot;:http://www.retrotec.com/products/duct_testing_systems/r31_economy_duct_tester/ duct testing systems. The field calibration plate is completely compatible with the Minneapolis Duct Blaster.


      h2. Detailed Duc-Tester Pressurization Field Calibration Check Procedure

# Tape the Field Calibration Plate to the flex duct flange &amp;
attach the red tube.
# Attach the flex-duct to the outlet side to pressurize the
duct. Install the Mid flow ring.
# Connect up as if you were testing a duct.
# Set to “Flow @ 25 Pa”, time averaging to 8 seconds. Adjust
the speed until PrA reads close to 25 Pa. Allow the flex
duct to straighten out to its full length.
# Wait for 30 seconds after fan speed stabilizes.

The _depressurization test_ is the same as the pressurization test, except the flex-duct is mounted on the duc-tester inlet.

If the measured flow of your duc-tester is less than 97 cfm _or_ greater than 106 cfm, our problems checklist will help you to determine a resolution.

h2. Common Problems

The &quot;field calibration manual&quot;:maunal.pdf provides a detailed checklist for each of these common problems. 

|*Problem*|*Problem Frequency*|*Typical Error*|*Details*|
|Wrong Range Configuration or Device|Constant|-80% to +400%|Setting the Digital Gauge to the wrong Range Config or Device is the most common error. Often occurs just after
a change of Range or Device.|
|Tubing Connections incorrect|Sometimes|20%|Especially for pressurizing houses and depressurizing ducts, tubes are hooked up incorrectly most of the time.|
|Plugged tubes|Seldom|20% to 200%|Wide range of errors but not that common.|
|Leaking tubes|Less Seldom|10% to 50%|Wide range of errors but not that common. Usually the
pressure source will restore some leaked away air but if excessive, pressure indications will fall.|
|Flex duct leaking|Slow degradation|1% to 25%|Very common but small. Always there to some degree. This procedure will identify a leaking duct so it may be
patched with duct tape.|
|Gauge channels read differently|Rare|1% to 20%|One of 2 channels reading differently. Uncommon but could be a big error. If both channels have an identical error, the effect on the result is negligible.|
|Gauge won’t zero|Rare|1% to 5%|One of 2 channels reading differently. Uncommon but
could be a big error. If both channels have an identical error, the effect on the result is negligible. It is the difference between the channels that causes the errors.|
   </content>
</entry>

<entry>
   <title>Wild Wind Tamer Wind Damping Kit</title>
   <link rel="alternate" type="text/html" href="http://www.retrotec.com/products/accessories/wild_wind_tamer_wind_damping_k/" />
   <id>tag:www.retrotec.com,2007:/products//2.127</id>
   
   <published>2007-04-12T20:34:31Z</published>
   <updated>2007-04-13T01:37:45Z</updated>
   
   <summary>Wild Wind Tamer design by Sheltair has four balanced tubes so each one has the same time constant. This wind tamer is useful in damping pressure fluctuations caused by heavier winds, up to 15 MPH. This design was developed from...</summary>
   <author>
      <name>Skot Nelson</name>
      
   </author>
   
      <category term="Accessories" scheme="http://www.sixapart.com/ns/types#category" />
   
   
   <content type="html" xml:lang="en" xml:base="http://www.retrotec.com/products/">
      Wild Wind Tamer design by &quot;Sheltair&quot;:http://www.sheltair.com/ has four balanced tubes so each one has the same time constant. This wind tamer is useful in damping pressure fluctuations caused by heavier winds, up to 15 MPH. This design was developed from research performed at &quot;Sheltair&quot;:http://www.sheltair.com/ which showed the older CGSB wind damping system did not work well in field tests because the shorter pressure legs would always dominate and the capacity tank would produce huge pressure swings when heated or cooled by the sun or from touching the tank.
      
   </content>
</entry>

<entry>
   <title>Basic Wind Damping Kit</title>
   <link rel="alternate" type="text/html" href="http://www.retrotec.com/products/accessories/basic_wind_damping_kit/" />
   <id>tag:www.retrotec.com,2007:/products//2.126</id>
   
   <published>2007-04-12T20:33:25Z</published>
   <updated>2007-04-13T01:39:37Z</updated>
   
   <summary>Retrotec&apos;s Basic Wind Damping Kit overcomes pressure fluctuations due to light wind effects of up to 10 mph. Has 25’ + 50’ exterior extension tube with damping capillary. Connects to outdoor red tube lead through the panel system....</summary>
   <author>
      <name>Skot Nelson</name>
      
   </author>
   
      <category term="Accessories" scheme="http://www.sixapart.com/ns/types#category" />
   
   
   <content type="html" xml:lang="en" xml:base="http://www.retrotec.com/products/">
      Retrotec&apos;s Basic Wind Damping Kit overcomes pressure fluctuations due to light wind effects of up to 10 mph. Has 25’ + 50’ exterior extension tube with damping capillary. Connects to outdoor red tube lead through the panel system.
      
   </content>
</entry>

<entry>
   <title>Retrotec Toolbags</title>
   <link rel="alternate" type="text/html" href="http://www.retrotec.com/products/accessories/retrotec_toolbags/" />
   <id>tag:www.retrotec.com,2007:/products//2.107</id>
   
   <published>2007-01-30T19:23:48Z</published>
   <updated>2007-01-30T19:25:52Z</updated>
   
   <summary>Retrotec toolbags come in a variety of sizes and colours, and are the perfect complement to your blower door system....</summary>
   <author>
      <name>Skot Nelson</name>
      
   </author>
   
      <category term="Accessories" scheme="http://www.sixapart.com/ns/types#category" />
   
   
   <content type="html" xml:lang="en" xml:base="http://www.retrotec.com/products/">
      Retrotec toolbags come in a variety of sizes and colours, and are the perfect complement to your blower door system.
      
   </content>
</entry>

<entry>
   <title>DU200 Hard Panel Adapter</title>
   <link rel="alternate" type="text/html" href="http://www.retrotec.com/products/accessories/du200_hard_panel_adapter/" />
   <id>tag:www.retrotec.com,2007:/products//2.106</id>
   
   <published>2007-01-30T18:33:22Z</published>
   <updated>2007-08-15T16:06:47Z</updated>
   
   <summary>Retrotec&apos;s DU200 Hard Panel Adapter allows you to use our new low flow fan with your existing hard panel system. You can use the low flow fan to to test houses that are extremely tight (ranging from one square inch...</summary>
   <author>
      <name>Skot Nelson</name>
      
   </author>
   
      <category term="Accessories" scheme="http://www.sixapart.com/ns/types#category" />
   
   
   <content type="html" xml:lang="en" xml:base="http://www.retrotec.com/products/">
      Retrotec&apos;s DU200 Hard Panel Adapter allows you to use our new &quot;low flow fan&quot;:/products/fans/duseries_low_flow_fans/ with your existing hard panel system.

You can use the low flow fan to to test houses that are extremely tight (ranging from one square inch of leakage to one square feet), providing a significant upgrade to your testing capabilities at an extremely modest cost.

h3. Part Number

PN217 -- DU200 Hard Panel Adapter

h2. Accessories

&quot;DU Series Low Flow Fans&quot;:/products/fans/duseries_low_flow_fans/
      
   </content>
</entry>

<entry>
   <title>2200 Digital Fan, Retrofit Kit</title>
   <link rel="alternate" type="text/html" href="http://www.retrotec.com/products/accessories/2200_digital_fan_retrofit/" />
   <id>tag:www.retrotec.com,2007:/products//2.104</id>
   
   <published>2007-01-29T17:08:11Z</published>
   <updated>2007-08-15T15:29:45Z</updated>
   
   <summary>Retrotec&apos;s 2200 Digital Fan retrofit kit upgrades your existing Retrotec series 2000 fan to the digital control features offered by Retrotec&apos;s new DM-2 digital gauge.</summary>
   <author>
      <name>Skot Nelson</name>
      
   </author>
   
      <category term="Accessories" scheme="http://www.sixapart.com/ns/types#category" />
   
      <category term="Fans" scheme="http://www.sixapart.com/ns/types#category" />
   
   
   <content type="html" xml:lang="en" xml:base="http://www.retrotec.com/products/">
      Retrotec&apos;s 2200 Digital Fan retrofit kit upgrades your existing Retrotec series 2000 fan to the digital control features offered by Retrotec&apos;s new DM-2 digital gauge.

h2. Why Upgrade?

Retrotec&apos;s &quot;DM-2A&quot;:http://www.retrotec.com/products/gauges/dm2_series_2_channel_digital_p/ offers automatic control features built into the gauge -- you can control your fan speed directly or choose to set a target room or flow pressure instead.

Automatic speed control makes testing easier than ever by eliminating the guess work related to fan speed.

h3. How Easy is the Upgrade?

Many fans can be upgraded easily by the end user by simply removing a few allan keys, removing your existing fan top and installing the new one.

Some older series 2000 fans need to be upgraded by trained Retrotec staff. Contact your Retrotec sales representative at 604.773.2865 for a cost estimate.

h3. Part Number

FN236
      
   </content>
</entry>

<entry>
   <title>Leakage Split Kit</title>
   <link rel="alternate" type="text/html" href="http://www.retrotec.com/products/accessories/leakage_split_kit/" />
   <id>tag:www.retrotec.com,2007:/products//2.102</id>
   
   <published>2007-01-22T21:32:31Z</published>
   <updated>2007-09-13T16:35:18Z</updated>
   
   <summary>Retrotec&apos;s Leakage Split Kit includes everything you need to conduct a two fan test with your Retrotec fans.</summary>
   <author>
      <name>Skot Nelson</name>
      
   </author>
   
      <category term="Accessories" scheme="http://www.sixapart.com/ns/types#category" />
   
      <category term="Modular Hard Panel Systems" scheme="http://www.sixapart.com/ns/types#category" />
   
   <category term="80" label="Leakage Split" scheme="http://www.sixapart.com/ns/types#tag" />
   <category term="82" label="Two Fan Test" scheme="http://www.sixapart.com/ns/types#tag" />
   
   <content type="html" xml:lang="en" xml:base="http://www.retrotec.com/products/">
      Retrotec&apos;s leakage split kit provides everything you need to conduct a &quot;two fan lower leaks&quot;:/fire_testing/technical_support/bcla_flex_duct_testing/flex_duct_testing_overview.php test with your Retrotec blower door systems. Using two of our &quot;Q56&quot;:/products/blower_door_systems/modular_hard_panel_systems/q56_automated_blower_door/ or &quot;Q5E&quot;:http://www.retrotec.com/products/blower_door_systems/modular_hard_panel_systems/q5e_blower_door/ systems you can conduct a &quot;below ceiling leakage&quot;:/fire_testing/technical_support/bcla_flex_duct_testing/flex_duct_testing_overview.php or &quot;subfloor test&quot;:/fire_testing/technical_support/testing_enclosures/subfloor_only_testing_using_wh.php in virtually any situation.

By letting you determine the location of leaks, the two fan test often produces results that clearly demonstrate a room passes the NFPA retention test in cases where a single fan test shows that a room fails.


      h2. Rapid Setup

A two fan test using Retrotec&apos;s leakage split kit is the _fastest_ way to set up a lower leaks test. While other methods can produce the same results, they may mean you need to spend hours setting up to conduct a single test.

h3. Get Proper Training!

The NFPA standard requires that all door fan test operators be &quot;thoroughly trained.&quot;:http://www.retrotec.com/fire_testing/enclosure_integrity_training/ Retrotec&apos;s &quot;Level Three Enclosure Integrity Training&quot;:http://www.retrotec.com/fire_testing/enclosure_integrity_training/level_3_leakage_split_measurem.php  arms you with the information you need to effectively perform a lower leaks test. Ask your Retrotec representative for information about training when you call.

h2. Leakage Split Kit Contents

Your Retrotec leakage split kit includes:

* A flex duct for your Retrotec series 2000 or 3000 fan. Your flex duct includes a protective carrying  case that&apos;s perfect for storage as well
* A field calibration plate for your modular hard panel system
* A subfloor test panel that fits most common raised subfloor tiles

Leakage split kits are available in _Imperial (U.S.)_ or _Metric_ sizing. Please specify when ordering.
   </content>
</entry>

<entry>
   <title>Remote Speed Control</title>
   <link rel="alternate" type="text/html" href="http://www.retrotec.com/products/accessories/remote_speed_control/" />
   <id>tag:www.retrotec.com,2007:/products//2.101</id>
   
   <published>2007-01-22T17:53:30Z</published>
   <updated>2007-01-22T17:55:53Z</updated>
   
   <summary>Retrotec&apos;s remote speed control allows for direct control over your fan speed. You can use the speed control with any Retrotec Series 2200, 3200 or 3300 fan. Convenient and easy to use, the speed control allows you to easily adjust...</summary>
   <author>
      <name>Skot Nelson</name>
      
   </author>
   
      <category term="Accessories" scheme="http://www.sixapart.com/ns/types#category" />
   
   
   <content type="html" xml:lang="en" xml:base="http://www.retrotec.com/products/">
      Retrotec&apos;s remote speed control allows for direct control over your fan speed. You can use the speed control with any Retrotec Series 2200, 3200 or 3300 fan.

Convenient and easy to use, the speed control allows you to easily adjust your fan on the fly.
      
   </content>
</entry>

<entry>
   <title>DM-2A, 3-Fan Splitter Box</title>
   <link rel="alternate" type="text/html" href="http://www.retrotec.com/products/gauges/dm2a_3_fan_splitter_box/" />
   <id>tag:www.retrotec.com,2007:/products//2.100</id>
   
   <published>2007-01-19T20:11:03Z</published>
   <updated>2007-08-15T15:33:47Z</updated>
   
   <summary>Retrotec&apos;s new DM-2A, 3-Fan Splitter allows you to control the speed of three separate fans using a single gauge. Combined with the DM-2A&apos;s powerful Set Pressure automatic control option, testing with multiple fans is now easier than ever.</summary>
   <author>
      <name>Skot Nelson</name>
      
   </author>
   
      <category term="Accessories" scheme="http://www.sixapart.com/ns/types#category" />
   
      <category term="Gauges" scheme="http://www.sixapart.com/ns/types#category" />
   
   
   <content type="html" xml:lang="en" xml:base="http://www.retrotec.com/products/">
      The Retrotec *DM-2A, 3-Fan Splitter* allows a single &quot;DM-2A&quot;:http://www.retrotec.com/products/gauges/dm2_series_2_channel_digital_p/ to control all three fans of a Retrotec Model QMG system simultaneously.  The &quot;DM-2A&quot;:http://www.retrotec.com/products/gauges/dm2_series_2_channel_digital_p/ control signal is split so that the speed of all three fans will increase and decrease together. 

The Splitter can be used with 3 standard-power 2200 or 2300 fans or 3 high-power 3300 series fans.

The Splitter can only be used with a &quot;DM-2A&quot;:http://www.retrotec.com/products/gauges/dm2_series_2_channel_digital_p/.  _It MUST NOT be used with a &quot;remote speed control&quot;:http://www.retrotec.com/products/accessories/remote_speed_control/ and cannot be used with a DM-2._

This Splitter _will not function_ with older 900, 2100, 3100, or 3200 fans. Some older Retrotec 2200 series fans may not be compatible -- please provide your Retrotec sales representative with your serial number by phone or email.

h3. Part Number

FN242
      h3. Splitter Connection

One &quot;DM-2A&quot;:http://www.retrotec.com/products/gauges/dm2_series_2_channel_digital_p/ is connected using an Ethernet-style cable to the Splitter.  Another 3 Ethernet-style cables connect the Splitter to 3 fans. 

h3. Detailed Connection Guide to Run 3 Fans

These steps describe how to use the DM-2A, 3-Fan Splitter to control your Retrotec Model &quot;QMG Blower Door&quot;:http://www.retrotec.com/products/blower_door_systems/three_fan_systems/

# Connect an Ethernet-style cable between a DM-2A’s _Speed Control_ port and the _DM-2A_ port on the splitter.  
# Connect 3 Ethernet-style cables between the 3 “Speed Control” ports on the splitter and the 3 Fans.
# Connect a Red tube from this DM2-A’s red pressure port and run it through the 3-fan panel in order to measure Room/Building Pressure on Channel A.
# Connect a Yellow tube from the Yellow pressure port on the DM-2A to the Flow Pressure port on the 3300 Drive Unit or 2300 fan in order to measure the Flow Pressure for Fan #1.
# Connect Yellow tubes to the Red and Yellow ports on a 2nd DM-2A or DM-2 to the Flow Pressure ports on Fan #2 and Fan #3 respectively.  Flow Pressure 2 and Flow Pressure 3 are displayed on Channels A and B of the 2nd gauge respectively.  
# Use Retrotec E2001 or DoorFan3.0 or custom software to translate flow pressures into flows and for other results.

_*Note:* the Advanced Calculation modes (Flow, ACH, EqLA, EfLA, etc) cannot be used on either gauge in this configuration._
   </content>
</entry>

<entry>
   <title>3300 Calibrated Fans</title>
   <link rel="alternate" type="text/html" href="http://www.retrotec.com/products/fans/3300_calibrated_fans/" />
   <id>tag:www.retrotec.com,2006:/products//2.85</id>
   
   <published>2006-12-05T22:57:07Z</published>
   <updated>2007-10-22T18:14:36Z</updated>
   
   <summary>Retrotec 3300-Series fans are designed for testing any residential house or enclosure from 12 ft2 (0.8 m2) of leakage down to tight houses and small enclosures with 15 in2 (97 cm2). The 3300-Series Fan uses a precision pieziometric ring on...</summary>
   <author>
      <name>Skot Nelson</name>
      
   </author>
   
      <category term="Fans" scheme="http://www.sixapart.com/ns/types#category" />
   
   
   <content type="html" xml:lang="en" xml:base="http://www.retrotec.com/products/">
      Retrotec 3300-Series fans are designed for testing any residential house or enclosure from 12 ft^2^ (0.8 m^2^) of leakage down to tight houses and small enclosures with 15 in^2^ (97 cm^2^).

The 3300-Series Fan uses a precision pieziometric ring on the inlet motor nacelle to ensure accurate flow readings.  Eight point fan mount makes this calibrated fan the strongest made.

Variable Frequency Drive has a built in computer that:

# Allows the DM-2A to control the fan. 
# Regulates the speed within a few RPM. 

The variable frequency drive will operate using anything from 100 to 240 Volts AC, 50 to 60 Hz with no loss of power.  

h2. Specifications

| | _CFM_ | _m^3^/ ~s~_ | _m^3^/h_ |
|_Maximum Flow (Free Air)_|8,100|3.823|13,762|
|_Open Range Maximum Flow (at 50 Pa)_|8,000|3.776|13,592
No flow loss at 50Hz !|
|_Open Range Minimum Flow (at 50 Pa)_|3,500|1.650|5,947|
|_Maximum Flow (at 300 Pa)_|4,000|1.888|6,796|
|_Minimum Flow (Range C1 at 10 Pa)_|38|0.018|65|
|_Accuracy_|\3. ± 5% without formal calibration
± 3% with formal fan and gauge calibration and Retrotec software|
|_Formal Calibration Meets_|\3. Canadian CGSB-149.1-2002 &amp; SuperE, USA ASTM E 779 – 03, European EN
13829 &amp; CEN, UK TM-23 Energy Standards.
NFPA 2001- 01 &amp; ISO 14520 Integrity standards.|
|_Dimensions_|\3. 26” x 25.5” x 9.5” (66 x 65 x 24 cm)|
|_Weight_|\3. Fan: 37 lb (16.8 kg) 3-Fan Panel Set: 21.5 lb (9.8 kg)|
|_Motor_|\3. 2.0 hp 22 amps at 120 Volts : 14 amps at 240 Volts|
|_Control_|\3. Using DM-2A (or optional Manual Speed Control)|
      
   </content>
</entry>

<entry>
   <title>Grill Mask</title>
   <link rel="alternate" type="text/html" href="http://www.retrotec.com/products/accessories/grill_mask/" />
   <id>tag:www.retrotec.com,2006:/products//2.84</id>
   
   <published>2006-12-05T21:47:18Z</published>
   <updated>2007-09-21T15:47:57Z</updated>
   
   <summary>Retrotec Grill Mask is the ideal solution for covering holes and duct registers when testing enclosures, houses or duct work. It provides a temporary sealing solution when you need it on the job site.</summary>
   <author>
      <name>Skot Nelson</name>
      
   </author>
   
      <category term="Accessories" scheme="http://www.sixapart.com/ns/types#category" />
   
   
   <content type="html" xml:lang="en" xml:base="http://www.retrotec.com/products/">
      Retrotec Grill Mask is ideal for covering holes and duct registers when testing enclosures, houses or duct work. Our self adhesive grill mask comes in easy to you perforated rolls perfect for use in the field. The adhesive sticks firmly, but won&apos;t peel paint.

h2. Quantities

Single rolls of grill mask can be ordered. Cases of three are available at a discounted price.

Each roll of Grill Mask is 160 feet long and 12 inches wide. Perforations every 12 inches make it easy to tear off.

h3. Part Number

GR109 - Case of three rolls, 160 feet in length each (12 pounds and is 12&quot; by 14&quot; by 8&quot; in size)
GR113 - Single Roll of Grill Mask

h2. Accessories

Retrotec&apos;s Grill Mask Dispenser makes applying large quantities of Grill Mark easy to do.
      
   </content>
</entry>

<entry>
   <title>Q52 Tight House Testing System</title>
   <link rel="alternate" type="text/html" href="http://www.retrotec.com/products/blower_door_systems/modular_hard_panel_systems/retrotec_model_q52_tight_house/" />
   <id>tag:www.retrotec.com,2006:/products//2.79</id>
   
   <published>2006-10-19T22:19:45Z</published>
   <updated>2007-01-23T18:52:26Z</updated>
   
   <summary>The Q52 is an automated low-flow blower-door for tight and super-tight houses. Retrotec Model Q52 consists of a DM-2A, a DU-220 Low Flow Fan and Single Fan Modular Panel Set-Up. DM-2A Automatic Digital Gauge Controls pressure or flow Results without...</summary>
   <author>
      <name>Skot Nelson</name>
      
   </author>
   
      <category term="Blower Door Systems" scheme="http://www.sixapart.com/ns/types#category" />
   
      <category term="Modular Hard Panel Systems" scheme="http://www.sixapart.com/ns/types#category" />
   
   
   <content type="html" xml:lang="en" xml:base="http://www.retrotec.com/products/">
      The Q52 is an automated low-flow blower-door for tight and super-tight houses.

Retrotec Model Q52 consists of a &quot;DM-2A&quot;:http://www.retrotec.com/products/gauges/dm2_series_2_channel_digital_p/, a &quot;DU-220 Low Flow Fan&quot;:http://www.retrotec.com/products/fans/duseries_low_flow_fans/ and Single Fan Modular Panel Set-Up.

h2. DM-2A Automatic Digital Gauge

* Controls pressure or flow
* Results without a computer!
** flow at any pressure, CFM50
** air-changes / hour, ACH50
** leakage area, EqLA @ 10 Pa
** air-flow / area (eg. m^3^/h/m^2^)

h2. DU-220 Automatic Calibrated Fan

* built-in computer controller
* 3 calibrated flow ranges for leakage measurement of tight and super tight buildings.
* Available in 110 and 240 Volts

|Airchanges at 50Pa|Maximum Volume|
|1.5|28,000 ft3 (793 m^3^)|
|3.0|14,000 ft3 (396 m^3^)|

* Hard Panels
* Set includes 1 Fan panel with 2 filler pieces, 1 XY Panel, 1 X panel, 1 fan strap, 1 roll of special panel seal and 1 panel case and 1 Hard Panel Adapter for the Low Flow Fan. 
      h2. Specifications

||_CFM_|_Litres/s_|_m^3^/h_|
|_Maximum Flow (Free Air)_|756|357|1284|
|_Maximum Flow (at 25Pa)_|700|330|1190|
|_Minimum Flow (Low Range at 10Pa)_|5|2|8|
|_Accuracy_|\3. Flow: ± 3%
Pressure: ± .2 Pa|
|_Calibration Meets_|\3. Canadian CGSB-149.1-2002 &amp; SuperE, USA ASTM E 779 – 03, European EN 13829 &amp; CEN, UK TM-23 Energy Standards.|

h3. Fits Door Sizes:

|_Door widths (min/max)_|32 to 48.75 inches (81 to 124 cm)|
|_Door height_|76.5 to 87 inches (194 to 221 cm)|
|_Fan_|14” x 14” x 12” (35 x 35 x 30 cm)	10.0 lb (4.5 kg)|
|_Hard Panels_|53” x 10” x 4” (134 x 25 x 10 cm)	14.2 lb (6.4 kg)|
|_Motor_|115 or 230V (185 Watt), Backward Curved Impeller|
|_Control_|Using DM-2A (or optional Manual Speed Control)|

h3. Q52 System Comes Complete With

|_Digital Gauge_|2-Channel DM-2A Digital Gauge with Automatic Control
10’ Umbilical for Fan Control, Power, Room Pressure and Flow Pressure
DM-2 Users Manual
Long-life rechargeable Ni-MH Batteries|
|_Low-Flow Fan_|DU220 Digital Low-Flow Fan with Automatic Control
Mid-Range and Low-Range Flow Plates|
|Hard Panels||
   </content>
</entry>

<entry>
   <title>Energy 2001 Software</title>
   <link rel="alternate" type="text/html" href="http://www.retrotec.com/products/software/energy_2001_software/" />
   <id>tag:www.retrotec.com,2006:/products//2.77</id>
   
   <published>2006-09-13T22:25:44Z</published>
   <updated>2007-11-30T18:09:07Z</updated>
   
   <summary>Retrotec&apos;s Energy 2001 software (E2001) is the ideal solution for performing residential energy audits. Compatible with the most commonly used energy auditing standards, E2001 is an essential component of every energy tester&apos;s toolkit. Supported Energy Standards United Kingdom - TM23:...</summary>
   <author>
      <name>Skot Nelson</name>
      
   </author>
   
      <category term="Software" scheme="http://www.sixapart.com/ns/types#category" />
   
   
   <content type="html" xml:lang="en" xml:base="http://www.retrotec.com/products/">
      Retrotec&apos;s Energy 2001 software (E2001) is the ideal solution for performing residential energy audits. Compatible with the most commonly used energy auditing standards, E2001 is an essential component of every energy tester&apos;s toolkit.

h3. Supported Energy Standards

* United Kingdom - TM23: 2000
* Japan - Japanese Standard
* Canada - CGSB149.10, EnerGuide, R-2000
*  ISO - CEN/TC 89
* United States - ASTM E779, UBC 905
* Holland - NEN 2686
* PFEER - Protection for Fire &amp; Emergency Evaucation Refuge
      h2. Download the Software

Download a free 30 day demonstration version of &quot;Retrotec&apos;s E2001 Energy Testing Software.&quot;:/downloads/E2001.zip.

h3. Software Licencing

Retrotec&apos;s Energy 2001 software is licenced on a _per fan_ basis. You can install the software on as many computers as you&apos;d like. The licence you purchase provides you with a calibration certificate specific to your fan. A separate licence is required for each fan which you will be using to conduct a door fan test.

E2001 Licences are non-transferrable.
   </content>
</entry>

</feed>