The 3200-Series fans are designed for testing any residential house or enclosure from 9 ft2 (0.8 m2) of leakage down to tight houses and small enclosures with 15 in2 (97 cm2).

The 3200-Series Fan uses a precision pieziometric ring on the inlet motor nacelle to ensure accurate flow readings. Eight point fan mount makes this calibrated fan the strongest made.

Variable Frequency Drive has a built in computer that:

  1. Allows the DM-2A to control the fan.
  2. Regulates the speed within a few RPM.

Will accept 100 to 240 Volts AC, 50 to 60 Hz in with no loss of power.

Specifications

CFMm3/ sm3/h
Maximum Flow (Free Air)8,1003.82313,762
Open Range Maximum Flow (at 50 Pa)8,0003.77613,592
No flow loss at 50Hz !
Open Range Minimum Flow (at 50 Pa)3,5001.6505,947
Maximum Flow (at 300 Pa)4,0001.8886,796
Minimum Flow (Range C1 at 10 Pa)380.01865
Accuracy± 5% without formal calibration
± 3% with formal fan and gauge calibration and Retrotec software
Formal Calibration MeetsCanadian CGSB-149.1-2002 & SuperE, USA ASTM E 779 – 03, European EN
13829 & CEN, UK TM-23 Energy Standards.
NFPA 2001- 01 & ISO 14520 Integrity standards.
Dimensions26” x 25.5” x 9.5” (66 × 65 × 24 cm)
WeightFan: 37 lb (16.8 kg) 3-Fan Panel Set: 21.5 lb (9.8 kg)
Motor2.0 hp 16 amps at 120 Volts : 9 amps at 240 Volts
ControlUsing DM-2A (or optional Manual Speed Control)